Do you have questions ?

Measurements and diagnostics

We measure to find a solution

We measure noise, sound insulation, reverberation and vibration to the standards – as an engineering assessment for a design, an expert opinion or diagnostics. Our goal is not the document but the solution: where the sound comes from, how much it has to drop and with what measure.

Do you need an official test report?

We do not issue accredited test reports. If you need a report for the Regional Health Inspectorate, the Regional Environmental Inspectorate or occupational health, contact an accredited inspection body directly. Our partner in projects with measurements is Spectri-Measurements – an inspection body accredited by the Bulgarian Accreditation Service (BAS).

Do you have a report showing an exceedance or an order to comply?

This is where we can help most. The report tells you how big the exceedance is, but not why it happens or how to fix it.

  1. Diagnostics – we find the source and the sound path: which machines, which side, which frequencies.
  2. Prediction – we calculate the reduction of each measure before any money is spent.
  3. Design and installation – noise barriers, enclosures, silencers, vibration isolation. We manufacture much of it ourselves.
  4. Control measurement before the repeat official inspection.

Solomed, Sofia – chillers next to a residential building. The official report showed 61.2 dB(A) at the dwellings against a limit of 55 dB(A). After the noise barrier, the repeat official measurement showed 55.0 dB(A) – within the limit.

Billa Trakia, Plovdiv – air-conditioning and refrigeration equipment below a residential block. 70.3 dB(A) outside the bedroom windows. Predicted after the measure – 53.7 dB(A); measured after installation – 54 dB(A).

Technical observer at an official measurement

If an official inspection is coming up, we can attend as a technical observer: checking that the operating mode of the machines, the points and the conditions follow the method. A wrong point or operating mode can cost you an exceedance that does not exist.

Types of measurement

Details of each type of measurement are on the pages below.

What we measure and to which standards

TypePurposeStandard / regulation
Noise from premises to dwellingsChillers, HVAC, machines, generatorsOrdinance No. 6 of 2006
Workplace noiseWorkshops and plants – assessment and measuresOrdinance No. 6 of 2005
Field sound insulationWalls, floors, doorsEN ISO 16283; Ordinance No. 4 of 2006
Reverberation and speech intelligibilityHalls, offices, classroomsEN ISO 3382
Field sound absorptionFinished linings, plastersSonocat sound intensity probe
Sound power and sound pathsMachines with steady noise, weak spots in partitionsSound intensity, EN ISO 15186
VibrationMachines, gyms, structuresDigiducer 333D01 accelerometer
Dynamic stiffnessResilient layers for floating floorsISO 9052-1
Studio analysisControl rooms and mixing studiosEBU Tech 3276, ITU-R BS.1116
Binaural recordingBefore/after comparison by listeningHEAD acoustics SQope

Equipment

  • Brüel & Kjær 2245 sound level meter, class 1 to IEC 61672;
  • Sonocat (Demcon) – sound intensity probe: in-situ sound absorption and sound power of steady noise sources;
  • Digiducer 333D01 digital accelerometer;
  • HEAD acoustics SQope binaural headset sensor;
  • iSEMcon EMX-7150 measurement microphone and REW software – for studio analysis.

Frequently Asked Questions

Is your measurement valid for the health or environmental inspectorate? No. Official purposes require a report from an accredited inspection body. Our measurement shows the cause and leads to a solution.

Why measure with you if I will need an official report later anyway? Because the official measurement only records the situation. If we first find and solve the problem, the official measurement is done once – after the measures.

How much does it cost? It depends on the type and the number of points – write to [email protected] or call 0883 400 061.