Client

Capital is a fast-growing trading platform, with offices in Europe, the UK, the Middle East and Australia. The company offers intuitive technology solutions, in-depth training and dedicated support for its clients.

Problem

Capital's offices follow the modern standard of interior design - predominantly glass partitions that create acoustic challenges. The main issues were:

  • Enhanced echo and sound reflection that degrade the quality of videoconferencing calls.
  • Increased level of noise in conference rooms, which makes communication difficult and leads to participants unconsciously raising their voices.
  • Lack of confidentiality - sound spreads easily outside the halls, creating a risk to sensitive information.

Problem Specifics

During the site visit we found that sound was passing not only through the glass partitions but also through the aluminium profiles of the building façade. Because they are hollow, they act as an acoustic conductor, creating a funnel-like effect. The director’s office was especially critical, as sound travelled from it to the open-plan office areas. The wall ends at a hollow aluminium window-frame profile with reduced sound insulation. Its sound reduction index is about 26 dB – well below that of the wall. With such a difference the weak point determines the overall result: even a narrow strip at 26 dB lowers the sound insulation of the whole wall. Example: in a 50 dB wall, a 26 dB profile occupying only 1% of its area (a 5 cm strip over the height of a 5 m long wall) lets through about 70% of the sound energy, and the overall insulation drops to about 45 dB.

Solution

After analyzing the client's problems and budget parameters, we proposed acoustic treatment of the conference rooms and part of the open spaces. The solution included:

  • Installation of specialized MDF profiles on the aluminum profiles of the window frames to stop resonance and sound transmission.
  • acoustic PET panel or rubber gaskets
  • Installation of acoustic panels on the walls and ceiling to reduce echo and improve the sound environment in the halls.
  • Replacement of the existing raster ceiling with one with acoustic properties, further reducing sound reflections.

Execution

After presentation of 3D visualization and discussion with the client were selected:

  • Round acoustic panels in green and yellow.
  • MDF solutions for acoustic insulation of the aluminium profiles of the suspended facade.
  • Acoustic panels for the ceilings.

After final approval, we drew up a detailed offer and went into production. Within 10 working days we produced 130 acoustic panels. Installation was done at a time convenient for the customer without disrupting the operational work of the company. The entire installation process took three working days.

Summary

Through the implemented acoustic solutions we achieved:

  • Reducing echo and improving the sound environment in conference rooms.
  • Increase confidentiality and reduce noise in open spaces.
  • Improving the overall acoustic comfort for employees and guests.

Materials used

    • Dedicated MDF boards for insulating the aluminium profiles of the suspended facade
    • Special Acoustic Pet Wool
    • Acoustic damasks

Similar project? See our service Acoustics and Soundproofing for Offices or contact us via the enquiry form.

Contact Us

телефон - икона

Contact Phone

0883 40 00 61

адрес - икона

Address

1 “5004” St., Knizhna Fabrika, 1528 Sofia

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
So that we can call you to clarify details.
Drop files here or
Accepted file types: jpg, jpeg, png, pdf, Max. file size: 20 MB.